Modular Chemical Detection System (SC-210)
 

The Modular Chemical Detection System is designed to provide the basic parts necessary to incorporate a chemical sensor into an existing network or device for demonstration purposes. Weighing less than four ounces (100g), the SC-210 base assembly can detect numerous volatile organic chemicals, emissions gases, nitroaromatics, and chemical warfare agents (CWA).  Optional modules can be added to increase response speed, increase sensitivity, to protect the sensor from extreme environments, and to build a handheld miniature gas chromatograph.

Winner of CONNECT Organization's Most Innovative Product Award in 2007's Security Technology Competition.   

As a stand-alone sensor this system can be easily worn as a badge or placed throughout a building to offer heightened workplace safety levels. In addition, the small size and rapid connectivity of the SC-210 allows it to be easily integrated into existing surveillance systems. This means two detection technologies can easily work together to detect multiple classes of dangerous chemicals while reducing the potential for false alarms.

Features:
•  Detects Volatile Organic Compounds and Chemical Warfare Agents
•  Turn on and detect within 15 seconds
•  Attach to a laptop via USB for real-time monitoring and data collection.
•  Proprietary chemicapacitive sensor array, available with optional gas-tight flow-path.
•  Interchangeable Sensor Array allows for rapid customization for
your specific needs.
•  Can sample up to once a second

Specifications:
Type SC-210
Substance Detected Volatile and Semi-Volatile Organic Compounds
Detection Principle MEMS Chemicapacitive Sensor Array
Sampling Method Ambient Air Sampling
Response Time Seconds (concentration dependent)
Power Source USB or 3.3V alkaline battery
Connectivity USB or RS485 serial
Battery Life 144 hours passive
Operating Temp. -5ºC to 70ºC
Display LED indicators, Laptop
Dimensions L1.1 x W2.7 x H0.8 in.
Weight Less than 4 oz.  <100 grams 
Accessories Air Pump, AC Adapter, metal case, Coin Cell  Battery, RS-485 Output, Laptop Computer

For applications requiring detection of:
Acetone, Acetonitrile, Acetophenone, Allyl alcohol, Ammonia, Benzene, Bromobenzene, Carbaryl, Carbon disulphide, DIMP, DMDNB, 2,6-DNT, 2,4-DNT, Ethyl acetate, Ethyl alcohol, Hydrogen cyanide, IPA, Methyl alcohol, Methyl benzoate, nitrobenzene, 1-Nitropropane, o-Nitrotoluene, Octane, Phenol, Styrene Oxide, Tetrahydrofuran, Toluene, HD (Mustard), GA (Tabun), GB (Sarin), GD (Soman).

 Call for Pricing for SC-210 (Modular Detection System)


Chemical Sensor Evaluation Kit (SC-EVLU)
 

The Chemical Sensor Evaluation Kit is Seacoast Science’s incorporates a miniature air pump and low-volume flow cell for the sensor in a convenient package.  This kit  is used to detect numerous volatile organic chemicals, emissions gases, nitroaromatics, and chemical warfare agents (CWA) to provide heightened protection for facilities personnel and first responders.

Same detection capabilities as the SC210 plus additional features:
•  Suitable for desktop or environmental chamber use
•  Air pump for faster sampling
•  Low-volume flow chamber

Specifications:
Type Evaluation Kit
Substance Detected Volatile and Semi-Volatile Organic Compounds
Detection Principle MEMS Chemicapacitive Sensor Array
Sampling Method Pump driven air flow
Response Time Seconds (concentration dependent)
Power Source USB
Connectivity USB
Operating Temp. -5ºC to 70ºC
Dimensions L3.5 x W2.7 x H0.8 inches
Weight Less than 1 pound
Accessories Metal enclosure,  Air pump, Sensor Arrays
 

Call for Pricing for SC-EVLU (Evaluation kit)


Ethanol Sensor Evaluation Kit (SC-M100)

The SC-M100 Ethanol Sensor Evaluation Kit is a simple chemical detector based on metal oxide technology.  This kit is designed to provide the basic parts necessary to incorporate a ethanol sensor into an existing network or device for demonstration purposes. SC-M100 is used to detect ethanol and has optional expansion capabilities to detect numerous volatile and semi-volatile organic chemicals, emissions gases, and toxic industrial chemicals allowing heightened protection for facilities personnel.

Features:
•  Alarms and activates PEL levels (1000 ppm)
•  Dual relays: fan (SPDT) & alarm (N.O.)
•  LED reflect system status
•  Wall mount enclosure with exposed sensor
•  No calibration required
•  2 Minutes warm up time
•  Up to 10 year lifetime
•  Micro computer state of the art design

Specifications:
Type SC-M100
Substance Detected Ethanol (10 Parts per Million)
Detection Principle Metal Oxide Sensor
Sampling Method Residual air-flow over sensor
Response Time Seconds (concentration dependent)
Power
Current
9-30 VAC or VDC, 0.9 VA; 
0.07A @ 12V, 0.03A @ 24V
Connections 7 max, # 20 wires, 6” long
Weight Less than 1 pound
Fan relay 10A, 250 VAC
5A, 100 VDC, 2500 VA, SPDT
Alarm relay 10A, 250 VAC
5A, 100 VDC, 2500 VA
Operating Environment 0ºC to 50ºC, 10-90 % RH

Call for Pricing for SC-M100 (Ethanol Detector)


Contact Seacoast Science to see how our prototypes can be tailored to meet your specific chemical detection needs.

 


Top

 
Site Search:      
 
 
  Sensor Systems
  Polymer Catalogs
  Ink Jet Systems
MINI-GC
 



 

Download the PDF version of our SC-210 Detection System.
Download the PDF version of our Ethanol Sensor System.
 



Home    



 |     About Us     |     Products     |     Technology     |     Contact
Copyright (c) 2010 Seacoast Science, Inc. All rights reserved.